DET-SMK/AC/1 & DET-SMK/AC/10 Smoke Alarm Troubleshooting Guide

DET-SMK/AC/1 & DET-SMK/AC/10

DET-SMK/AC/1 & DET-SMK/AC/10 SMOKE ALARM TROUBLESHOOTING GUIDE

Troubleshooting guide and other resources for the DET-SMK/AC/1 & DET-SMK/AC/10 smoke alarms from MATelec Australia

TESTING THE ALARM

TESTING YOUR DET-SMK/AC/1 & DET-SMK/AC/10 SMOKE ALARMS

We recommend testing your DET-SMK/AC/1 & DET-SMK/AC/10 Smoke Alarms monthly to confirm they are working correctly.

Step 1

CHECK GREEN LED

Firstly, check that the green LED on the face of the alarm is illuminated. This means that mains power is connected.

Step 2

TEST BUTTON

Press and hold the Test button on the face of the alarm for two seconds. The alarm will sound 3 short chirps, pause for 1.5 seconds, and then continue sounding until you release the button. This confirms the alarm is working.

Step 3

CHECK WIRED INTERCONNECTED ALARMS

If your alarms are hardwired interconnected, test each unit individually. While holding the Test button, the triggered alarm will sound, and any interconnected alarms should also activate. Have someone check all other alarms are sounding while this button is pressed.

Step 4

CHECK RED FLASHING LED

After testing, ensure the red LED on each alarm is flashing. This will continue for approximately three minutes, indicating the test was successful.

VIDEO

Testing the Alarm

How to test MATelec DET-SMK/AC/1, /10 & DET-SMK/RF/AC/1, /10 Smoke Alarms

LED SIGNALS & ALERTS

LED SIGNALS & AUDIBLE ALERTS REFERENCE TABLE

Need to add table content in here

VIDEO

Understanding the LED Signals and Audible Alarms

Understanding the LED signals and audible alarms on MATelec DET-SMK/AC/1 and /10 Smoke Alarms

VIDEO

Using HUSH Mode & Locating Triggered Alarms

Using HUSH mode & locating triggered alarms on MATelec DET-SMK/AC/1 & /10 and RF/AC/1 & /10 Smoke Alarms

FACTORY RESETTING

FACTORY RESETTING DET-SMK/AC/1 & DET-SMK/AC/10 SMOKE ALARMS

To restore your DET-SMK/AC/1 & DET-SMK/AC/10 Smoke Alarms to their factory settings, follow the steps.

Step 1

ISOLATE MAINS POWER

Isolate the mains power by pushing the button on the side of the alarm to detach the head from the base and have it swing down from the ceiling.

Step 2

REMOVE BATTERY

Remove the backup battery.

Step 3

TEST BUTTON

Press and hold the Test button for 15 seconds to discharge any residual or stored power in the unit.

Step 4

REPEAT ON WIRED INTERCONNECTED ALARMS

Repeat these on all hardwired interconnected alarms before replacing batteries or reattaching head units to the bases.

Step 5

SECURE ALARM

Insert fresh backup batteries, then swing each head unit back up and secure it onto its base until it clicks into place.

VIDEO

Factory Resetting the Alarm

How to Factory Reset MATelec DET-SMK/AC/1 and /10 Smoke Alarms

BATTERY INFORMATION

DET-SMK/AC/1 SMOKE ALARM BATTERY INFORMATION

The DET-SMK/AC/1 Smoke Alarm includes a one-year alkaline backup battery designed to keep the alarm operating during a power outage. This battery should be replaced every 12 months.

Step 1

AUDIBLE CHIRP AND LED FLASH

A single chirp accompanied by a red LED flash every 48 seconds indicates the backup battery needs replacing. This alert cannot be silenced until the battery is changed.

Step 2

PUSH BUTTON

Press the Push button on the side of the alarm to release it from its base. Open the alarm body and replace the backup battery with a new one.

Step 3

SECURE ALARM

Close the alarm body securely, then refit the unit onto its base until it clicks into place.

VIDEO

DET-SMK/AC/1 & DET-SMK/RF/AC/1 Battery Replacement

Replacing the battery in MATelec DET-SMK/AC/1 and DET-SMK/RF/AC/1 Smoke Alarms

BATTERY INFORMATION

DET-SMK/AC/10 SMOKE ALARM BATTERY INFORMATION

The DET-SMK/AC/10 Smoke Alarm contains a non-replaceable 10-year battery designed to last for the full life of the unit.

Step 1

AUDIBLE CHIRP AND LED FLASH

When the alarm reaches the end of its service life, it will emit one chirp with two red LED flashes every 48 seconds.

Step 2

CHECK EXPIRY

This signal means the entire unit must be replaced. You can also confirm this by checking the printed expiry date on the back of the alarm.

VIDEO

DET-SMK/AC/10 Unit Replacement

Battery & Unit Replacement for MATelec DET-SMK AC & RF Smoke Alarms (1-Year & 10-Year Models)

STILL NEED HELP?

STILL NEED HELP?

Reach out to our trained and qualified technical support for Smoke Alarms.