TESTING THE ALARM

TESTING YOUR FSA-30000 SMOKE ALARMS

We recommend testing your FSA-30000 Smoke Alarms monthly to confirm they are working correctly.

Step 1

TEST BUTTON

Press and hold the Test button for two seconds. The alarm will sound three short chirps, pause for 1.5 seconds, and then continue sounding until you release the button.

Step 2

ALARMS SOUND

For interconnected alarms, press and hold the Test button for five seconds. The alarm you are testing will sound first, followed by all interconnected alarms, confirming that the wireless network is operating correctly. After the test, check that the red LED on each alarm is flashing. This will continue for three minutes to indicate a successful test.

VIDEO

Testing the Alarm

How to test MATelec FSA-30000 Smoke Alarms

LED SIGNALS & ALERTS

LED SIGNALS & AUDIBLE ALERTS REFERENCE TABLE

Need to add table content in here

VIDEO

Understanding the LED Signals and Audible Alarms

Understanding the LED signals and audible alarms on MATelec FSA-30000 Smoke Alarms

VIDEO

Using HUSH Mode & Locating Triggered Alarms

Using HUSH mode on MATelec FSA-30000 Smoke Alarms

FACTORY RESETTING

FACTORY RESETTING FSA-30000 SMOKE ALARMS

To restore your FSA-30000 Smoke Alarms to their factory settings, follow the steps.

Step 1

TURN ALARM OFF

Remove the smoke alarm from the mounting bracket and ensure the switch located on the back of the alarm is in the OFF position.

Step 2

PRESS CONTROL/ON

Press and hold the CONTROL button while moving the internal switch to the ON position. The red LED on the alarm face will illuminate for 3 seconds.

Step 3

UNPAIR ALARMS

When the red LED turns off, release the CONTROL button. The LED will illuminate again for another 3 seconds. During this time, press the CONTROL button once to unpair and reset the smoke alarm. The red LED will then flash for several seconds.

Step 4

ALARM RESET

When the red LED stops flashing, the smoke alarm has been returned to its factory default state.

VIDEO

Factory Resetting the Alarm

How to Factory Reset MATelec FSA-30000 Smoke Alarms

BATTERY INFORMATION

FSA-30000 SMOKE ALARM BATTERY INFORMATION

FSA-30000 Smoke Alarms are powered by a 10-year non-replaceable sealed battery.

If the low battery indicator occurs (one flash every 40 seconds accompanied by one chirp every 40 seconds), the smoke alarm has reached end of life and must be replaced.

ALARM PAIRING

FSA-30000 SMOKE ALARM PAIRING INSTRUCTIONS

Follow the below steps to pair the FSA-30000 alarm with another FSA-30000 smoke alarm. When one alarm is triggered, all alarms in the connected network will alarm.

Step 1

TURN ON ALARMS

Rotate the mounting bracket to the ON position to switch each smoke alarm on.

Step 2

CONFIRM OPERATION

Press and hold the CONTROL button for 2 seconds.

The alarm will chirp indicating correct operation.

Step 3

CHOOSE MASTER ALARM

Choose one smoke alarm to act as the MASTER unit.

  1. Apply the MASTER sticker (provided).
  2. This ensures future SLAVE alarms can be added easily

Recommended: Choose a smoke alarm located centrally within the residence. If your system includes both wired and wireless alarms, designate a centrally located wired alarm as the MASTER.

Step 4

ENTER PAIRING MODE

Press the CONTROL button three times within 2 seconds on the MASTER alarm.

The BLUE LED will illuminate for 30 seconds, indicating pairing mode is active.

Step 5

MASTER ALARM PAIRING

The MASTER unit will automatically search for SLAVE alarms.

Pairing mode will time out after 30 seconds of inactivity.

If pairing does not complete, repeat Step 4 to restart pairing mode.

Step 6

CONNECT TO SLAVE ALARMS

On the SLAVE unit, press the CONTROL button three times within 2 seconds.

  1. If the LEDs on both alarms turn GREEN for 3 seconds, pairing is successful.
  2. The MASTER alarm LED will return to BLUE, ready to accept the next SLAVE.
  3. The SLAVE alarm LED will turn off, indicating it has completed pairing.
Step 7

REPEAT FOR MORE ALARMS

Repeat Step 6 for each additional SLAVE alarm.

VIDEO

Pairing FSA-30000 Alarms

Pairing FSA-30000 Smoke Alarms

VIDEO

Pairing FSA-60000 Alarms with FSA-30000

How to pair a MATelec FSA-60000 Smoke Alarm with FSA-30000 Smoke Alarms

VIDEO

Pairing DET-SMK/RF/AC/1 & /10 Alarms with FSA-30000

Pairing MATelec DET-SMK/RF/AC/1 and /10 Smoke Alarms with a MATelec FSA-30000 Smoke Alarm

VIDEO

Pairing FSA-30000 Alarms with FSA-90000 Remote

Pairing the MATelec FSA-90000 Remote with FSA-30000 and FSA-60000 Smoke Alarms

SUPPORT MATERIAL

RELATED RESOURCES

Filters

0resources

Loading…

STILL NEED HELP?

STILL NEED HELP?

Reach out to our trained and qualified technical support for Smoke Alarms.

FSA-30000 Smoke Alarm Troubleshooting Guide | MATelec Australia